$0.00 $0.00
Please choose options.Back to top
Close
$0.00 $0.00
Home > All Products > Brand > VDW > VDW FlexMaster Dental Ni-Ti Opening Engine Files 19mm (6Pcs/Pack) (V040357019000)

VDW FlexMaster Dental Ni-Ti Opening Engine Files 19mm (6Pcs/Pack) (V040357019000)

SKU: VZ011690
0.0 (0)
37 Sold
$62.00 $0.00
Received successfully
Coupon Code
CONTINUE SHOPPING
Wholesale:
$56.99
5-max
    Please select the information you wantX
Quantity:
  • VDW FlexMaster Dental Ni-Ti Opening Engine Files 19mm (6Pcs/Pack) (V040357019000),www.Dental-Genuine.com,VDW FlexMaster Dental Ni-Ti Opening Engine Files 19mm (6Pcs/Pack) (V040357019000)
  • VDW FlexMaster Dental Ni-Ti Opening Engine Files 19mm (6Pcs/Pack) (V040357019000),www.Dental-Genuine.com,VDW FlexMaster Dental Ni-Ti Opening Engine Files 19mm (6Pcs/Pack) (V040357019000)
  • VDW FlexMaster Dental Ni-Ti Opening Engine Files 19mm (6Pcs/Pack) (V040357019000),www.Dental-Genuine.com,VDW FlexMaster Dental Ni-Ti Opening Engine Files 19mm (6Pcs/Pack) (V040357019000)
  • VDW FlexMaster Dental Ni-Ti Opening Engine Files 19mm (6Pcs/Pack) (V040357019000),www.Dental-Genuine.com,VDW FlexMaster Dental Ni-Ti Opening Engine Files 19mm (6Pcs/Pack) (V040357019000)
1/1
  • VDW FlexMaster Dental Ni-Ti Opening Engine Files 19mm (6Pcs/Pack) (V040357019000),www.Dental-Genuine.com,VDW FlexMaster Dental Ni-Ti Opening Engine Files 19mm (6Pcs/Pack) (V040357019000)
  • VDW FlexMaster Dental Ni-Ti Opening Engine Files 19mm (6Pcs/Pack) (V040357019000),www.Dental-Genuine.com,VDW FlexMaster Dental Ni-Ti Opening Engine Files 19mm (6Pcs/Pack) (V040357019000)
  • Description

Product UseApplicable instruments used in dental root canal treatment.Product CompositionThe product consists of a working part and a rod or part. The working part is stainless steel or a preservative alloy.Flex MasterR Intro File Flex MasterR nickel-titanium opening file usage:1. First, use X-ray diagnosis and estimate the working length.2. Start to create a direct channel to the root canal hole and use a hand file to make a slide.3. Use the Flex MasterR nickel-titanium opening file to completely expand the crown.4. Use lubricants during root canal preparation and clean the bottom regularly.5. Use a stopper to mark about 2/3 of the estimated working length.Basic Principles of Cleaning and Disinfection1. It is recommended to use a mechanical method (disinfector) to clean and disinfect the instrument plate. Due to the low effectiveness and number of reuse of manual methods, manual methods including ultrasound are only considered when the instrument cannot be mechanically treated. Instruments should be pretreated in every case.2. After using the instruments, remove tooth and dentin residues immediately (up to 2 hours) and do not allow residues to dry into any form of contamination: residues can lead to a risk of contamination!3. After using the instruments, place the instruments that need to be cleaned, pre-sterilized and temporarily stored in a temporary rack with appropriate cleaning and disinfection solutions (up to 2 hours).4. A temporary cleaning rack with a new foam tray must be used for each patient.5. Then, wash the instruments under running water (at least 3x1 minute) or in any suitable disinfectant. And check for any visible contaminants. The disinfectant should be acetaldehyde-free (acetaldehyde can fix blood stains), certified by an authority (e.g. VAH/DGHM or FDA certificate or CE label), suitable for instrument disinfection and compatible with the instrument (see chapter "Material resistance"), and only use a clean soft brush to remove dirt manually, or a clean soft cloth for this step. Metal brushes or steel wool must not be used.6. Please note: The disinfectant used for pretreatment is only for personal protection and cannot replace disinfection after cleaning.Mechanical Cleaning/DisinfectionHigh temperature disinfection (disinfector/CDU) When purchasing a disinfector, always make sure that:1. It is certified by an authority (e.g. VAH/DGM or FDA certificate CE label according to DIN EN IS015883)2. High temperature disinfection (at least 10 minutes at 93°C or A value ≥ 3000) is possible (residues on the instrument may cause chemical disinfection risk)3. The instrument disinfection procedure is appropriate and provides sufficient cleaning cycles.4. Only sterile water with low bacterial content (10 CFU/ml) and no endotoxin (<0.25EU/ml, such as high purity water HPWI) is used.5. Regularly maintain and inspect the disinfection equipment.

CUSTOMER REVIEWS

0.0 0 Reviews
Write a review
Frequently Bought Together
more
Frequently Bought Together